Skip to main content
We may get paid by partner for deals, including promoted items

Menu

15% off

Product Description

Victron Energy Autotransformer Split Phase 120/240V 100 amps Blue. While the step up and step down functions are fairly straightforward split phase output balancing may require some more attention. Consider for example a 30A 120/240V split phase supply. The supply could be the grid a generator or two stacked inverters. Some of the loads connected are 240V others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer for example will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current or current unbalance will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A the other leg may be drawing no more than 10A and increasing the 240V load for example will result in an overload of one leg while the other leg still has spare capacity. Theoretically the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 72 kVA. In case of 20A unbalance the practical maximum will be 30 x 120 + 10 x120 = 48kVA or 67percent of the theoretical maximum. The solution is an Autotransformer. By leaving the neutral of the split phase supply unused and connecting an Autotransformer to create a new neutral as shown in figure 1 any load unbalance is absorbed by the Autotransformer. In case of a 30A supply the load can be increased to 72kVA and a 20A load unbalance will result in one leg supplying 40A and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A. Ground relay for use with Multi or Quattro Inverter/Chargers included When operating in inverter mode the neutral output of the inverter/charger must be connected to ground to guarantee proper functioning of a GFCI. In case of a split phase supply the neutral must be grounded. For this purpose a grounding relay is built in the autotransformers enclosure. The relay is controlled by the 230/240V Multi or Quattro. (The internal grounding relay in the 230/240V Multi or Quattro must be disabled) Temperature protected In case of overheating the Autotransformer is disconnected from the supply. Reset is manual. An alternative to stacked inverters The alternative to stacking two 120V inverters to provide a 120/240V split phase supply is a 240V inverter with an additional Autotransformer. Specifications for Victron Energy Autotransformer - Split Phase 120/240V: Manufacturer: Victron Energy Color: Blue Amperage: 100 amps Package Contents: Victron Energy Autotransformer - Split Phase 120/240V Victron Energy ITR000100101: Autotransformer Split Phase 120/240V 100 amps Blue

Victron Energy Autotransformer Split Phase 120/240V 100 amps Blue

$509.15 $599.00 15% Discount
You save $89.85
In Stock at Optics Planet
Price verified 2d ago
Buy Now at Optics Planet
Secure checkout Easy returns
or compare prices

Product Details

More from Victron Energy

Lotz Outdoors
Last Updated:
Aug 30, 2026 01:40 AM
Lotz Outdoors
Last Updated:
Aug 30, 2026 01:40 AM
Lotz Outdoors
Last Updated:
Aug 30, 2026 01:40 AM
Lotz Outdoors
Last Updated:
Aug 30, 2026 01:40 AM
Lotz Outdoors
Last Updated:
Aug 30, 2026 01:40 AM