Fluke T6-1000 Electrical Tester with FieldSense Technology

Fluke T6-1000 Electrical Tester with FieldSense Technology

Sale $ 349.99
Fluke T6-1000 Electrical Tester with FieldSense Technology, Fluke T6-1000 Electrical Tester We know working in electrical boxes jammed with wires can be challenging when youre trying to find a safe metallic contact point. Now, with Fluke's T6-1000 with integrated FieldSense technology you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.* * Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations. Features Be safer: Measure voltage to 1000 V ac through the open fork, without test leads. Be faster: No need to open covers or remove wire nuts. Be more efficient: Simultaneously measure voltage and current. Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mmA^2). Go beyond simple detection. Actually measure ac voltage and current values without test leads. Includes: Test leads, (2) AA batteries, quick start guide, safety sheet. Measurement SpecificationsFunctionRequires test leadsRangeResolutionAccuracy[1]FieldSense ac voltage true-rmsNo1000 V1 VA (3% + 3 counts) 45 Hz - 66 Hz[2][3]FieldSense ac current true-rmsNo200.0 A0.1 AA (3% + 3 counts) 45 Hz - 66 HzFieldSense frequency (Hz)No45 Hz 66 Hz1 HzA (1% + 2 counts)[3]Volts ac true-rmsYes1000 V1 VA (1.5% + 2 counts) 45 Hz - 66 HzVolts dcYes1000 V1 VA (1% + 2 counts)ResistanceYes2000 &@8486;1 &@8486;A (1% + 2 counts)Yes20.00 k&@8486;0.01 k&@8486;Yes100.0 k&@8486;0.1 k&@8486;Safety1000 V CAT III 600 V CAT IVAccuracy[1]: A ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18C to 28C (64F to 82F) with relative humidity to 90%. AC measurements are ac-coupled, RMS responding. Accuracy[2]: Add 3% without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. Accuracy[3]: FieldSense is specified from 16 V to 100% of range. General SpecificationsCalibration1-year calibration cycleDimensions61.1 x 259.3 x 43.8 mmJaw opening17.8 mmWeight0.35 kg (0.78 lb)TemperatureOperating-10C to +50C (14F to 122F)Storage-30C to +60C (-22F to +140F)AltitudeOperating2,000 m (6,562 feet)Storage10,000 m (32,808 feet)Relative Humidity0% to 90%, 5C to 30C (41F to 86F)0% to 75%, 30C to 40C (86F to 104F)0% to 45%, 40C to 50C (104F to 122F)Battery Type and Life2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSenseTemperature coefficient0.1 x (specified accuracy) /C for 28C0.1 x (specified accuracy) /C for 28CSafetyIEC/EN 61010-1: Pollution Degree 2Electromagnetic EnvironmentIEC/EN 61326-1: Portable
Fluke T6-1000 Electrical Tester with FieldSense Technology
$349.99  
Fluke T6-1000 Electrical Tester with FieldSense Technology